--> --> -->

Blogs

03
Jul 2023

Automated CCI Testing of Pre-filled Syringes Using E-Scan RTX

Automated CCI Testing of Pre-filled Syringes Using E-Scan RTX

Automated Container Closure Integrity Testing (CCIT) is a specialized form of testing that focuses on verifying the integrity of the container closure systems of several types of containers used to store and transport products. This can include vials, pre-filled syringes, bottles, pouches, and other types of containers. The container closure system includes the closure device (such as a stopper or cap) and the container or package itself (such as a glass or plastic vial or bottle), and it is essential to ensure that it is properly sealed so that it does not allow any leaks or contaminants to enter the container.

Automated CCI testing of pre-filled syringes involve using specialized testing equipment and techniques to simulate real-world conditions and test the container closure system's integrity. This testing process can be done in the laboratory by an operator or fully automated to increase efficiency and accuracy.

Testing Pre-filled Syringes Using E-Scan RTX

The E-Scan RTX platform is a modular, fully automated container closure integrity solution for pre-filled syringes. The RTX is a practical and dependable CCI solution with a dynamic robotic design that is adjusted to meet your production needs. This robust, flexible platform uses MicroCurrent HVLD technology, a revolutionary form of HVLD that is the optimal CCI solution for fragile, high-risk biologic liquids. It is appropriate for batch release testing at the production line, in the lab, and provides a quick PASS/FAIL result with a test cycle of only seconds.

A robotic arm will track and pick up nested syringe trays from a standard single lane conveyor. The robot removes the syringes from the nested tray and rotates the syringes through two test stations, one to detect needle shield defects and the other to inspect the rest of the syringe body. The test starts automatically and gives a fixed PASS/FAIL signal on completion of the test. An adjustable failure reference can be set to allow PASS/FAIL based on a predetermined LOD (limit of detection) setting in the initial recipe. After testing, syringes are automatically loaded back into the syringe tray, defective syringes are collected in the reject tray.

Benefits of E-Scan RTX

  • MicroCurrent HVLD technology is effective across all parenteral products, including biologics and extremely low conductivity liquids including sterile water (WFI).
  • Listed in USP Chapter 1207 as a recommended method for parenteral liquid package inspection.
  • Robust method and good Signal-Noise-Ratio between good and defective products.
  • Low voltage exposure reduces the production of ozone.

Automated pre-filled syringe testing is critical to ensuring the safety and efficacy of pre-filled syringes used in the pharmaceutical industry. By using automated testing techniques, manufacturers can ensure that the container closure system is reliable and free from defects, reducing the risk of contamination or other safety concerns.

pre-filled syringe testing, package integrity testing, e-scan rtx, container closure integrity testing, container closure integrity
238
Popup Popup